Overview Netatmo actuator



Switches the Legrand, BTicino and Bubendorff devices that are connected through the Netatmo cloud (e.g. Home + Control): switches and sockets, dimmers, shutters and fans. One block per device. Which inputs and outputs have an effect depends on the device; the others have no effect or stay at 0.

Inputs

EA
On/off
Non-zero switches on, 0 switches off (switches, sockets, dimmers). Acts when the value changes. During the first seconds after the controller starts the value is only stored and not sent, so that a restart does not overwrite settings made in the Netatmo app. Optional. Not connected: nothing is ever sent.
HE
Brightness %
Brightness 0 to 100 % (dimmers). Changes in quick succession are combined, the last value is sent after 1 second. Acts when the value changes. During the first seconds after the controller starts the value is only stored and not sent, so that a restart does not overwrite settings made in the Netatmo app. Optional. Not connected: nothing is ever sent.
PO
Position %
Target position 0 to 100 % (shutters; 0 = closed, 100 = open). Changes in quick succession are combined, the last value is sent after 1 second. Acts when the value changes. During the first seconds after the controller starts the value is only stored and not sent, so that a restart does not overwrite settings made in the Netatmo app. Optional. Not connected: nothing is ever sent.
ST
Stop
Evaluated is the change from 0 to non-zero: the shutter stops. Optional. Not connected: no stop.
LS
Fan speed
Fan speed 1 or 2 (ventilation units). Values below 1 are ignored. Acts when the value changes. During the first seconds after the controller starts the value is only stored and not sent, so that a restart does not overwrite settings made in the Netatmo app. Optional. Not connected: nothing is ever sent.


Outputs

EA
State on/off
1 = switched on.
HE
Brightness %
Current brightness of a dimmer in %.
PO
Position %
Current position of a shutter in % (0 = closed, 100 = open).
LE
Power W
Measured power in W (sockets and meters with measurement).
ER
Reachable
1 = the device is connected to the Netatmo cloud, 0 = Netatmo reports it as unreachable.
DA
Data current
1 = Netatmo renewed the values within the timeout. 0 = no data since start, account not signed in or timeout expired.


Parameters

Account
Optional. The Netatmo account block used to query this device. The selection is only shown when the project contains several accounts. Not set: the first account in the project.
Select device
Opens the list of devices the account found at Netatmo, filtered to the devices that fit this block. The selection sets device name and device ID. The Studio must be connected to the controller and the account signed in.
Device name
Name of the device at Netatmo, for display only.
Device ID
Netatmo identifier of the device, room or home. Can also be entered manually. Empty: the block delivers no values and shows »Device?«.
Timeout data outdated
If no new data arrives from Netatmo within this time (minutes), »Data current« drops to 0. The other outputs keep their last known value. 0 = never outdated. Default 30 min.