Overview Netatmo detector



Integrates a Netatmo smoke detector, CO detector, door and window contact (Door Tag) or the indoor siren. One block per device. Alarm and fault come from the events that the block Netatmo account queries in the event interval, i.e. with a delay of up to one interval.

The block does not replace a fire alarm system. It is suitable for reporting and forwarding, not as the only means of alarm.

Inputs

SI
Siren
Indoor siren only: non-zero sounds the siren, 0 stops it. Acts when the value changes. During the first seconds after the controller starts the value is only stored and not sent, so that a restart does not overwrite settings made in the Netatmo app. Optional. Not connected: nothing is ever sent.


Outputs

AL
Alarm
1 = the detector reported smoke or CO, 0 = alarm ended or hushed. With the indoor siren: 1 = the siren is sounding. After a controller restart 0 until the next event arrives.
ST
Fault
1 = tampering or a fault of the detection chamber was reported.
KO
Contact open
Door Tag only: 1 = door or window open.
BA
Battery low
1 = the battery of the device is low.
ER
Reachable
1 = the device is connected to the Netatmo cloud, 0 = Netatmo reports it as unreachable.
DA
Data current
1 = Netatmo renewed the values within the timeout. 0 = no data since start, account not signed in or timeout expired.


Parameters

Account
Optional. The Netatmo account block used to query this device. The selection is only shown when the project contains several accounts. Not set: the first account in the project.
Select device
Opens the list of devices the account found at Netatmo, filtered to the devices that fit this block. The selection sets device name and device ID. The Studio must be connected to the controller and the account signed in.
Device name
Name of the device at Netatmo, for display only.
Device ID
Netatmo identifier of the device, room or home. Can also be entered manually, but for a siren only via »Select device«, otherwise »Alarm« stays at 0. Empty: the block delivers no values and shows »Device?«.
Timeout data outdated
If no new data arrives from Netatmo within this time (minutes), »Data current« drops to 0. The other outputs keep their last known value. 0 = never outdated. Default 30 min.