Netatmo room| Shows and controls a heating room of the Netatmo energy products (thermostat, radiator valves, OpenTherm, Smarther). Netatmo controls per room, not per valve: all valves of a room follow the same setpoint. One block per room. |
Inputs |
||
| SW |
Setpoint |
New setpoint in °C. A change switches the room to manual with this setpoint, for the duration at input DA. Several changes in quick succession are combined, the last value is sent after 2 seconds. Acts when the value changes. During the first seconds after the controller starts the value is only stored and not sent, so that a restart does not overwrite settings made in the Netatmo app. Optional. Not connected: nothing is ever sent. |
| MO |
Mode |
0 = auto (back to the schedule), 1 = manual with the setpoint at input SW (not connected: the current setpoint from Netatmo), 2 = max (full power). Acts when the value changes. During the first seconds after the controller starts the value is only stored and not sent, so that a restart does not overwrite settings made in the Netatmo app. Optional. Not connected: nothing is ever sent. |
| DA |
Duration min |
Duration in minutes for manual and max, read when setpoint or mode changes. Optional. Not connected or 0: the default duration set in the Netatmo app. |
Outputs |
||
| IT |
Actual temperature |
Measured room temperature in °C. |
| SW |
Setpoint |
Current setpoint in °C. |
| MO |
Mode |
0 = auto (schedule), 1 = manual, 2 = max, 3 = away, 4 = frost guard, 5 = off. |
| EN |
Setpoint until |
End of a manual setpoint as text DD.MM.YYYY hh:mm, empty in schedule mode. |
| FO |
Window open |
1 = Netatmo detected an open window (temperature drop). |
| HA |
Heating request % |
Heating power requested by the room, 0 to 100 %. |
| ER |
Reachable |
1 = the device is connected to the Netatmo cloud, 0 = Netatmo reports it as unreachable. |
| BA |
Battery low |
1 = the battery of at least one device in the room is low. |
| DA |
Data current |
1 = Netatmo renewed the values within the timeout. 0 = no data since start, account not signed in or timeout expired. |
Parameters |
||
| Account |
Optional. The Netatmo account block used to query this device. The selection is only shown when the project contains several accounts. Not set: the first account in the project. |
|
| Select device |
Opens the list of devices the account found at Netatmo, filtered to the devices that fit this block. The selection sets device name and device ID. The Studio must be connected to the controller and the account signed in. |
|
| Device name |
Name of the device at Netatmo, for display only. |
|
| Device ID |
Netatmo identifier of the device, room or home. Can also be entered manually. Empty: the block delivers no values and shows »Device?«. |
|
| Timeout data outdated |
If no new data arrives from Netatmo within this time (minutes), »Data current« drops to 0. The other outputs keep their last known value. 0 = never outdated. Default 30 min. |
|