KLF 200 / VELUX| This
function block controls VELUX io-homecontrol actuators (roller
shutters, windows, awnings, venetian blinds, gates, lights) through
the VELUX KLF 200 gateway and reads back their positions. Communication uses the local KLF 200 API (TCP port 51200, TLS-encrypted). Enter the IP address and password of the KLF 200. The password is the setup key printed on the device (Wi-Fi password). The easiest way is to read the actuators with the Search actuators button while the controller is connected. After Apply, the Studio asks whether the addresses should be generated right away. The addresses then carry the actuator names from the KLF 200. Without the search, set the number of actuators and create the addresses with Create addresses. Three addresses are created per actuator:
Note: The automatic search only works if the controller is connected to the software and is itself connected to the KLF 200. If the system is operated via APP, special protective measures should be taken (e.g. a private VPN access). The system should never be freely accessible from the internet. No connection to the KLF 200: The cause is shown in the error log of the controller.
|
Outputs |
||
| ER |
Error counter |
Number of communication errors (-1 = software without SSL support) |
Parameters |
||
| IP address |
IP address of the KLF 200 | |
| Port |
TCP port of the KLF 200 API (default: 51200) | |
| Password |
Setup key of the KLF 200 (printed on the device) | |
| Timeout (ms) |
Connection timeout in milliseconds | |
| Number of actuators |
Number of actuators to control (determines the number of generated addresses) | |
| Actuator list |
Assignment of the actuators (NodeID/name/type). Filled automatically by the search. | |
| Debug |